Order Form
Online Ordering Coming Soon
|
|
 |
GRS-6032A
30 MHz Analog-Digital Scope
The GRS-6032A sets a standard in performance and economy. It comes with two professional scopes, can be operated as a real time 30Mhz analog oscilloscope and become a full function digital storage oscilloscope by pressing a button.
Features
- DC~30MHz, 100MSa/s, 2kW/CH x 2
- 2 Channels, 4 Traces
- Equivalent Time Sampling of 500MSa/s max.
- Waveform SAVE / RECALL (M0~M9)
- Pre-trigger Function 0 ~ 10 div.
- ROLL Mode to 100s/div.
- Max. Sweep Rate 10ns/div.
- Cursor Readout Function: △V, △T, 1/△T
- ALT-MAG Function (x5, x10, x20)
- Panel Setting SAVE / RECALL 10 sets. (M0~M9)
Specifications
| CRT |
| Type |
6-inch CRT D14-363GY, 2kV |
| Inten and Focus |
Front panel control |
| Illumination |
Front panel control |
| Z-axis Output |
| Sensitivity |
at least 5V (TTL) |
| Polarity |
positive going input decrease intensity |
| Max. input voltage |
30V (DC+AC peak) |
| Input impedance |
approx. 33k Ohms |
| Vertical System |
Sensitivity and Accuracy |
1mV ~ 2mV/DIV ±5%, 5mV ~
20V/DIV ±3%, 14 calibrated steps
in 1-2-5 sequence |
| Variable Continuously |
2.5:1 ~ min. 50V/DIV |
Bandwidth (-3dB)
5mV ~ 20V/DIV - DC ~ 30MHz
1mV ~ 2mV/DIV - DC ~ 7MHz
Rise Time
5mV ~ 20V/DIV - Approx. 11.7nS
1mV ~ 2mV/DIV - Approx. 50nS |
Vertical Mode |
CH1, CH2, DUAL(ALT or CHOP) |
| Chopper Frequency |
Approx. 250kHz |
| Sum or Difference |
CH1+CH2, CH1-CH2 |
| Invert |
CH2 |
| Input Impedance |
Approx. 1M Ohms ±2% //
approx. 25pF |
| Input Coupling |
AC, DC, GND |
| Maximum Input Voltage |
400V (DC + AC peak) |
Horizontal System |
Sensitivity and
Accuracy |
1mV ~ 2mV/DIV±5%, 5mV ~
20V/DIV±3%, 14 calibrated steps in 1-2-5 sequence |
| Sweep Time |
0.2µS/DIV ~ 0.5S/DIV, 20 steps
selectable in 1-2-5 sequence |
Maximum
Sampling Rate |
500MS/s for Equivalent time
sampling 100MS/s for normal sampling |
| Storage Bandwidth |
Single shot: DC-5MHz (-3dB)
Repetitive event: DC-30MHz ±5DIV |
| Dynamic Range |
±5DIV |
| Memory Length |
| Axquisition Memory |
2kW/CH*2, 1kW/CH (equivalent) |
| Save REF Memory |
1kW/CH*10 with back-up memory |
| Display Memory |
1kW/CH*4 waveorm (max) |
| Sweep Time |
| Equivalent |
0.2µs/DIV; 0.5µs |
| Normal |
1µs/DIV~0.1s/DIV |
| Roll |
0.2s/DIV~100s/DIV Equivalent:
0.2s/DIV; 0.5 s/DIV |
| Sweep Magnification |
x5, x10, x20 |
| Max. Sweep Time |
50nS/DIV (10nS/DIV ~ 40nS/DIV
are uncalibrated) |
| MAG Interpolation |
DOT, Linear |
| ALT-MAG Function |
YES |
| Acquire Mode |
Sample, Peak Detect (>25ns),
Envelope, Per-sist, Average (2~256) |
| Operation Mode |
Auto, Norm, Single, Single-Roll,
Roll, X-Y, Average (2~256), Run/Stop |
| Smoothing Function |
Dot joint ON/OFF selectable |
| Pre-Trigger |
0~10DIV in 0.02DIV steps |
| X-Y Operation |
X-axis: CH1, Y-axis: CH2 |
| Storage Bandwidth |
DC~30MHz (-3dB) |
| Display Resolution |
H:100points/DIV; V:25 points/DIV |
Waveform SAVE/ RECALL |
10 sets (REF0~REF9) |
| Cursor Readout |
| Cursor Measurement |
ΔV, ΔT, 1/ΔT |
| Readout Intensity |
Adjustable |
| Output Signal |
| CH1 Signal Output |
Voltage: approx. 20mV/DIV
(with 50 Ohms terminated) |
| Calibrator Output |
Voltage: 0.5V ±3% |
| Interface |
RS-232C Interface |
Power Source |
| AC 100V/120V/ 230V ± 10%, 50/60Hz |
Accessories |
Power cord x 1, Instruction manual x 1, Probes(10:1/1:1) x 2 |
Dimensions and Weight |
| 275(W) x 130(H) x 370(D) mm, Approx. 7.2kg |
|
  |
|
 |
|